Circuit Simulation with Flux
Flux is an AI hardware engineer. It simulates circuits directly from the chat. Circuit simulation helps you quickly verify circuit behavior, troubleshoot design issues, and optimize component values without having to set up a separate simulation environment.
Overview
With circuit simulation, you can:
Simulate a circuit that you describe, or a SPICE netlist that you give
Simulate your existing schematic by pulling component values directly from your design
Run transient, AC, DC, operating point, Monte Carlo, temperature sweep, noise, and parameter sweep analyses
Get automatic extraction of key metrics like -3 dB frequency, ripple, and gain
Generate plots and visualizations (Bode plots, waveforms, etc.)
Rerun or modify previous simulations without starting from scratch
Access a built-in library of SPICE models for common components
Simulate a circuit
Ask Flux to simulate the circuit. Give the component values and the source conditions.
When you ask for a simulation, Flux:
Analyze your request to understand the circuit you want to simulate
Look for the built-in SPICE model library and reference templates for relevant examples
Generate a SPICE netlist based on your description (or your existing schematic)
Run the simulation
Automatically extract structured metrics (e.g., -3 dB frequency, ripple, gain)
Iterate if errors occur, fixing syntax, convergence, or time step issues and retrying automatically
Generate plots or visualizations if requested
Provide a detailed interpretation of results
Simulating Your Existing Schematic
Flux simulates circuits that you have already designed in Flux. When you ask Flux to analyze your schematic, Flux reads the exact component values, net connections, and topology from your design so simulations use your actual R, C, L, and voltage source values rather than assumed defaults.
Supported Analysis Types
Flux runs these analysis types:
AC Analysis
Frequency-domain analysis for filters, amplifiers, and frequency response characterization. Flux extracts:
-3 dB cutoff frequency
DC gain and peak gain (in dB)
Roll-off slope (dB/decade)
Transient Analysis
Time-domain analysis for step responses, switching circuits, and waveform characterization. Flux extracts:
Voltage ripple measurements (Vpp, ripple %)
Min, max, and average values for each signal
Steady-state behavior
DC Analysis
DC sweep analysis for transfer characteristics, bias point verification, and operating point analysis.
Operating Point Analysis
Static DC operating point analysis to check node voltages and branch currents throughout a circuit.
Monte Carlo Analysis
Ask Flux to model part tolerances across multiple circuit runs.
Open the Chat panel and describe the component tolerances and results that you need. Flux returns the simulated value distributions and plots.
Temperature Sweep
Ask Flux to analyze circuit behavior across a temperature range.
Open the Chat panel and give Flux the temperature range and measurements. Flux returns the results for each temperature step.
Noise Analysis
Ask Flux to measure circuit noise over a frequency range.
Open the Chat panel and name the circuit nodes and frequency range. Flux returns the noise density and integrated noise results.
Parameter Sweep
Ask Flux to compare circuit behavior across component values.
Open the Chat panel and name the component values and measurements. Flux returns a result for each value in the sweep.
Plots and Visualizations
Flux generates plots and charts from simulation results. You can request visualizations like Bode plots, transient waveforms, or any other graphical representation of simulation data.
When you request a plot, the simulator generates it automatically and displays it inline in the chat.
Rerunning and Modifying Simulations
After running a simulation, you can ask Flux to rerun it with modifications. Flux reuses the working netlist from the previous simulation and only changes what you request, making iterations fast and reliable.
SPICE Model Library
Flux has a built-in library of SPICE models covering common components like op-amps, comparators, MOSFETs, and more. When your simulation requires a specific component model, Flux includes the appropriate model automatically.
You do not need to provide SPICE models yourself. Describe the component you want to use (e.g., "TL072 op-amp" or "LM393 comparator"), and Flux finds and includes the correct model.
SPICE Netlist Format
If you prefer, you can provide your own SPICE netlist directly. Flux reads standard SPICE netlist syntax. Here's a simple example:
Important notes:
Always include a
.printdirective to specify which node voltages or branch currents to outputEnd the netlist with
.endInclude appropriate analysis commands (e.g.,
.tran,.ac,.dc,.op)
Example Use Cases
Here are some common use cases for circuit simulation:
Passive Filter Analysis
Active Filter Analysis
Current Analysis
Voltage and Current Ripple
RC Timing and Oscillators
Comparing Circuit Designs
Tips for Effective Simulations
To get the best simulation results:
Be specific about component values; specify resistance, capacitance, and other component values with appropriate units (e.g., 1k, 10uF, 100nH).
Describe the circuit topology, clearly explain how components are connected, or let Flux read it from your schematic.
Specify the analysis type; name the transient, AC, DC, operating point, Monte Carlo, temperature sweep, noise, or parameter sweep analysis.
Ask for specific metrics; tell Flux what you want to measure (e.g., "-3dB frequency", "output ripple", "gain at 1kHz").
Request visualizations: Ask for Bode plots, waveforms, or comparison charts to see your results graphically.
Iterate on results: Use the rerun capability to quickly explore different component values or circuit configurations.
Break down complex circuits: For very complex circuits, consider simulating smaller subsections first.
Automatic Error Handling
Flux handles common simulation issues by iterating on the netlist:
Syntax Errors
If the netlist has syntax errors, Flux:
Identify the specific error in the simulator output
Generate a corrected version of the netlist
Retry the simulation with the corrected netlist
Convergence Issues
For convergence problems, Flux:
Identify potential causes of convergence failure
Add appropriate
.OPTIONSstatements (e.g.,RELTOL,ABSTOL,ITL1,ITL4)Adjust initial conditions or component values if necessary
Retry with alternative simulation parameters
Time Step Issues
If time step errors occur, Flux:
Adjust
.TRANparameters to use smaller time stepsAdd